The bearing bush of high voltage motor is burnt. How to solve it?

 1. Check the lubricating oil cooling system for blockage and leakage. Because the blockage of the cooler will cause the temperature of the lubricating oil to rise, and the leakage of the cooler will cause the lubricating oil to be mixed with water and the lubricating oil to deteriorate; Both causes can cause tile burning.

 
2. Check whether the oil inlet of the bearing bush is sufficient. You can ensure that the system has sufficient lubricating oil by adjusting the diameter of the throttle ring at the oil inlet of the bearing or adjusting the system pressure.
 
3. Check whether the oil supply system pipeline is blocked. If it is blocked, clean the system pipeline.