Atlas air compressor does not load reasons
1.Failure or blockage of air compressor regulating valve
2.Incorrect setting of pressure switch
3.The cylinder diaphragm is worn and leaking
4.Leakage of pipeline or water filter cup
5.Failure of air inlet valve, such as loose connecting rod bolt
6.Discharge solenoid valve failure makes the control gas discharge
7.loading solenoid valve damage
Atlas air compressor does not load processing method
1.Replace or clean the capacity adjustment valve
2.Replace or reset the pressure switch
3.Replace the diaphragm
4.Replace the water filter cup or eliminate the leakage
5.Eliminate the butterfly valve mechanism failure or replace the butterfly valve
6.Eliminate the drain solenoid valve failure or replace the drain solenoid valve
7.Eliminate the loading solenoid valve failure or replace the loading solenoid valve