Reasons for burning tile of air compressor
1,Deterioration of lubricating oil or too many impurities.
2,Insufficient oil supply or no oil supply.
3,Shaft tile displacement makes the internal oil circuit of air compressor blocked.
4,Shaft tile and connecting rod tile are strained or the clearance is too small.
Air compressor burning tile fault judgment and elimination method
1,Check the oil quality and impurity content of lubricating oil, compare with the use standard, and replace it immediately when it exceeds the standard.
2,Check the lubricating oil feed pressure of air compressor, whether the oil pipeline is broken or blocked, the pressure is not enough to adjust, clean or replace the failed pipeline immediately.
3,Check the installation position of the shaft tile, the oil hole of the shaft tile and the oil hole of the box must be aligned.
4,Check whether the shaft tile or connecting rod tile is burnt or strained, and check whether the crankshaft diameter is damaged or worn when cleaning and replacing the tile, and should be replaced when it exceeds the standard.
5,Check and adjust the shaft tile clearance.