Air compressors are used in various production fields, and due to the different quality of the equipment, there are more or fewer failures in the use of repair cases. The common failures include high-temperature shutdown, frequent loading and unloading, and failure to start due to high voltage. When the air compressor fails many users often do not know how to respond, the following briefly discusses the screw air compressor pressure is too high to start and low voltage response measures.
1, the voltage is too high to start
Screw compressor units are equipped with a voltage protection device, the general equipment low voltage automatic-start, high voltage automatic shutdown is a normal phenomenon. Pressure-related is automatically controlled by the pressure switch or pressure sensor. Therefore, if the machine has pressure problems, you only need to adjust the pressure of the compressor and adjust the pressure switch action range, and the start pressure set on the sensor. The pressure switch has a RANGE and DIFFE, and the RANGE can be adjusted according to the company's production requirements, while the DIFFE is generally not moved. Adjust the start/stop pressure value set by the pressure sensor. You can find the pressure setting options on the compressor panel for adjustment.
2.Voltage is too low
This is a problem that many users are prone to, and the harm is often greater. For example, if the grid voltage is only 360V, then 380V to 220V will need to replace the transformer, but the cost of replacing the transformer is often high, so it is recommended to consult the manufacturer whether the motor can bear it, and then decide the follow-up method.
If it is a variable frequency air compressor solution is more. For inverter models, due to the circuit principle inside the inverter: the inverter changes the output power by changing the output voltage, however, this voltage cannot be higher than the input voltage. If the input voltage is only 360V, then a 380V rated voltage machine can only output to 360V, the voltage is not enough, the inverter will lift the current. As long as the current is not too large, it is also possible to use it, if the current is too large, you can also reduce the upper limit frequency to ensure the normal operation of the machine.
Faults inevitably occur during the use of screw air compressors, and only by mastering the basic fault handling methods can we ensure the normal operation of the unit.