Two-stage screw compressor frequent start/stop and high-temperature alarm causes and solutions

Two-stage screw air compressor air compressor system some of the problems, most of the design, commissioning and other aspects of unreasonable caused by the main reasons and solutions are as follows.

Two-stage screw air compressor frequent start-stop cause analysis.

First,  air compressor operating parameters are set incorrectly. Handling measures: air compressor operating parameters should be reset.

Second,  The check valve is set on the external outlet pipe of the air compressor equipment. Measure: The check valve on the external outlet of the air compressor should be canceled.

Thrid, The volume of the buffer tank is too small. Measures: The volume of the buffer tank should be increased, and the total volume of the buffer tank can be selected according to 1/8~1/6 of the total exhaust volume of the air compressor.

Air compressor high temperature alarm

First,  If it is a water-cooled type, consider whether the cooling water cooling effect is not good, whether the water is not enough, or whether it is caused by pipe scaling. Treatment measures: first use the water meter to determine whether the cooling water quantity meets the requirements; by analyzing the water quality of the cooling water, determine whether the cooling water is in a state of easy scaling, and the cooling water system should be dosed in time.

Second,  The indoor temperature of the air compressor station is too high, and the ventilation system of the station room may be unreasonable. Treatment measures: If it is a negative pressure system, the exhaust air volume should be increased. For a positive pressure system, the inlet air filter of the positive pressure fan should be checked for blockage, resulting in lower efficiency.

Third, the temperature control switch control valve may be damaged. Treatment measures: Replace the new temperature control switch control valve.
 