After the screw air compressor is installed with the dryer, the compressed air still contains water.

1.The capacity of the post-treatment drying equipment configured by the air compressor is insufficient. If your instantaneous air consumption is large, the capacity of the post-treatment dryer will be insufficient, resulting in water in the air.
2. The air tank itself has the function of ponding. Because you forget to drain, a lot of water in it is not discharged, which will also lead to water in the compressed air. Therefore, the drain valve under the air tank should be opened regularly to drain the water.
3. The air humidity around the air compressor station is high
4. Handle dryer failure
5. The last reason may be the problem of pipeline design. The design gradient of the compressed air pipe of the screw air compressor is not enough, and the condensed water in the pipe cannot be completely discharged in time, which will also cause water.