Solution to Leakage of Air Compressor Safety Valve
1. Check and replace damaged safety valves: When a safety valve is found to be damaged, professional personnel should be contacted in a timely manner for inspection and maintenance, or a new safety valve should be replaced.
2. Replace the sealing ring or sealing surface: For air leakage problems caused by aging or wear of the sealing ring or sealing surface, the corresponding sealing ring or sealing surface should be replaced to ensure the sealing performance of the valve.
3. Reinstall safety valve: When reinstalling the air compressor safety valve, ensure that its position, direction, and height meet the specified requirements to ensure the normal operation of the valve.
4. Strengthen maintenance: Regularly inspect, repair, and replace parts of the safety valve of the air compressor to ensure its normal working condition.
5. Install pressure relief valve: Install a pressure relief valve on the exhaust pipeline of the air compressor. When the system pressure exceeds the set value, it can automatically release pressure, reduce the working load of the safety valve, and reduce the occurrence of air leakage.