Air compressor tank maintenance
1、Before each use, check the connection parts for looseness and air leakage, if there is any abnormality, immediately tighten the maintenance and exclude it.
2, The maximum working pressure of the tank is 0.8MPa, in the work of overpressure is strictly prohibited.
3,To be in the pressure dial, the upper limit of the working pressure of the tank to make the red line marking.
4, pressure gauge, safety valve are safety accessories, pay attention to the usual maintenance and maintenance. To be in accordance with national standards for the cycle, by the government technical supervision departments regularly for its safety certification and calibration. Among them, the pressure gauge every six months, calibration, safety valves every year, calibration, calibration.
5、Pressure gauge of gas storage tank should return to 0 position before filling.
6, The work, the operator should be on the tank and related air compression equipment at least two inspections, found that the situation is disposed of in a timely manner, and carefully do a good job of operating records.
7, The end of the work, let off the compressed air in the tank, open the tank under the sewage valve, let off the vapor condensate and other dirt.